200A plug
DTCEE High-Current Connection Series
Configure a 200A connection around your equipment
Choose a Type A or Type B surface-mounted plug for a fixed pin-side connection, or a high-current industrial connector for a movable socket-side cable connection. DTCEE offers 200A models in 4-pole and 5-pole configurations with IP67 protection and control-signal provision.
Type A surface-mounted plug with flange mounting and bottom cable entry.
Choose the connection format before the model
The connection role determines which product family belongs at each end of the circuit. Type A and Type B products are fixed, pin-side surface-mounted plugs. The high-current industrial connector is a movable, socket-side cable end. A complete detachable connection pairs a pin side with a compatible socket side.
Type B: top cable entry for bracket-mounted installations
The Type B surface-mounted plug uses bracket fixing, a top cable entry, and a cable buckle. Select this layout when the fixed installation is arranged for cable approach from above and the cable needs support at the enclosure.
Type A: bottom cable entry for flange-mounted installations
The Type A surface-mounted plug uses flange fixing and a bottom cable entry. Select this layout when the mounting surface and cable route are designed around a flanged fixed connection with the incoming cable below the plug body.
Industrial connector: movable socket side for flexible cable
The high-current industrial connector provides the socket-contact side for a movable cable connection. Use it where the cable end must move to the equipment or fixed plug.
200A series specifications at a glance
| Product format | 200A 4-pole model | 200A 5-pole model | Mounting or cable role | Protection | Ambient temperature | Mating cycles |
|---|---|---|---|---|---|---|
| Type B surface-mounted plug | DT75251B | DT75256B | Bracket fixed; top cable entry; cable buckle | IP67 | −22 to 122 °F (−30 to 50 °C) | 5,000 |
| Type A surface-mounted plug | DT75251A | DT75256A | Flange fixed; bottom cable entry | IP67 | −22 to 122 °F (−30 to 50 °C) | 5,000 |
| High-current industrial connector | DT75211 | DT75216 | Movable socket-side cable connection | IP67 | −22 to 122 °F (−30 to 50 °C) | 5,000 |
The 5-pole configuration is 3P+N+E. The high-current series includes control-signal provision; confirm the signal-pin arrangement and wiring for the selected model.
Explore DTCEE 200A connection products

Type B fixed plug for bracket-mounted layouts with top cable entry and cable support.
High Current Surface-Mounted-Plug Type B
This fixed pin-side product suits enclosure layouts where the incoming cable approaches from above and needs support at the connection point.
- Rated current200A
- Pole options4-pole or 5-pole
- 200A modelsDT75251B / DT75256B
- InstallationBracket fixed, top cable entry, cable buckle
- Protection ratingIP67
- Ambient temperature−22 to 122 °F (−30 to 50 °C)
- Mating cycles5,000
- Control-signal cable routingFrom the top or enclosure, as required by the selected configuration

Type A fixed plug for flange-mounted layouts with bottom cable entry.
High Current Surface-Mounted-Plug 160a 200a 250a 400a
This fixed pin-side product suits equipment or enclosure layouts designed for a cable route below the connection point.
- Rated current200A
- Pole options4-pole or 5-pole
- 200A modelsDT75251A / DT75256A
- InstallationFlange fixed, bottom cable entry
- Protection ratingIP67
- Ambient temperature−22 to 122 °F (−30 to 50 °C)
- Mating cycles5,000
- Control-signal cable routingFrom the top or enclosure, as required by the selected configuration

Movable industrial connector for the socket-contact side of a compatible 200A connection.
High Current Industrial Connector 160a 200a 250a 400a Best Quality
This movable socket-side connector terminates a flexible cable for a detachable connection to a compatible fixed pin-side product.
- Rated current200A
- Pole options4-pole or 5-pole
- 200A modelsDT75211 / DT75216
- Connection roleMovable socket-side cable connector
- Protection ratingIP67
- Ambient temperature−22 to 122 °F (−30 to 50 °C)
- Mating cycles5,000
- Auxiliary featureControl signal pin
Confirm the complete electrical match
A valid 200A selection is the intersection of the circuit requirements, connector interface, installation layout, and environmental conditions. Use the following sequence to prepare a model request.
- Define the connection role. State whether the required end is a fixed pin-side plug or a movable socket-side connector, and provide the existing mating-part model when replacing or extending a system.
- Confirm the power system. Provide rated voltage, frequency, phase arrangement, and the function of each conductor. Specify 4-pole or 5-pole only after determining whether the circuit requires neutral and protective earth.
- Match the interface. A 200A rating and the same pole count do not establish compatibility. Confirm rated voltage, frequency, clock position, keying, contact arrangement, pin/socket relationship, and the manufacturer-approved mating model.
- Choose the installation format. Select Type A for flange fixing with bottom entry or Type B for bracket fixing with top entry and a cable buckle. Check cable approach, bend space, mounting space, and access for mating and removal.
- Coordinate the cable and protection. Match conductor size and cable diameter to the selected terminals and entry hardware. Coordinate the cable ampacity and upstream overcurrent protection with the load, duty, and applicable electrical rules.
- Verify the final model documents. Obtain the model-specific drawing, terminal data, installation instructions, mating list, and applicable compliance documents before releasing the purchase order or machining the mounting surface.
Keep the IP67 connection effective in service
IP67 identifies dust protection and protection against temporary immersion under defined test conditions. It does not by itself establish suitability for permanent immersion, high-pressure washdown, corrosive chemicals, ultraviolet exposure, impact, or hazardous locations. Describe those exposures separately so the complete installation can be evaluated.
The assembled connection depends on both mating products, seals, cable entries, covers, and locking features. Use compatible parts with the required protection state, install the product in its permitted orientation, provide drainage where needed, and prevent cable pull or bending load from reaching the terminals. An incomplete seal or a lower-rated mating component governs the protection of the connection.
A qualified electrical professional should install and wire the product under the model-specific instructions and applicable local rules. Before energizing, verify the model and ratings, pin/socket pairing, conductor functions, protective-earth continuity, terminal tightness, cable restraint, entry seals, unused-entry closures, lock operation, phase sequence where relevant, and coordination with upstream protection.
Request a 200A plug recommendation and quote
Send Yueqing Datong Electrical Co., Ltd. the electrical configuration, connection role, installation layout, cable data, operating environment, quantity, and destination. DTCEE can use those details to identify the appropriate 4-pole or 5-pole product and confirm the information needed for your order.
- Phone: +86 13336970867
- Email: info@dtcee.com
- WhatsApp: +86 13336970867
- Address: No. 5 Kaichuang Road, Henghe Industrial Zone, Panshi Town, Yueqing City, Wenzhou, Zhejiang, China
DTCEE