3 phase plug
IEC 60309 Industrial Power Connections
DTCEE wall-mounted three-phase plugs provide a fixed pin inlet for industrial equipment and power distribution assemblies. This selected C-series range covers 16A, 32A, 63A, and 125A models, with 4-pole or 5-pole circuits and IP44 or IP67 protection.
Choose the complete electrical configuration before ordering: system voltage and frequency, current rating, 3P+E or 3P+N+E, clock position, mating connector, installation conditions, and required compliance documents.
DTN5351 / DTN5451 wall-mounted three-phase plug
IEC 60309 Three-Phase Plugs for Fixed Equipment Inputs
The products on this page are IEC 60309-style wall-mounted plugs with male pins. They mount on equipment, enclosures, or fixed structures to create a detachable three-phase power inlet. A compatible cable-mounted connector with female contacts completes the connection.
This product scope differs from NEMA straight-blade and twist-lock devices commonly used in North America. A NEMA designation cannot be substituted for the IEC configuration shown here, even when voltage or current appears similar.
For a U.S. project, confirm the facility supply, installation rules, and authority requirements before selecting a model. The IEC/EN conformity information available for this range does not by itself establish a UL or CSA listing for a specific model.
Select the Electrical Configuration Before the Model
Start with the equipment nameplate and the actual supply system. The phrase “3 phase plug” does not identify the voltage, frequency, neutral requirement, current rating, or compatible interface.
| Selection step | Choose from | Selection rule |
|---|---|---|
| 1. Voltage and frequency | This featured range is shown at 400V; verify the exact model clock position and frequency | Match the equipment and site supply. Do not select from housing color alone. |
| 2. Neutral requirement | 4-pole 3P+E or 5-pole 3P+N+E | Use 3P+E when the load does not require neutral. Use 3P+N+E when the circuit requires three phases, neutral, and protective earth. |
| 3. Rated current | 16A, 32A, 63A, or 125A | Coordinate the accessory rating with design current, duty, cable ampacity, terminals, and upstream protection. |
| 4. Environment | IP44 or IP67 | Identify exposure to splashing, dust, water jets, temporary immersion, condensation, impact, temperature, and corrosion. |
| 5. Mating side | Matching female cable connector | Match standard family, current size, pole count, voltage, frequency, clock position, keying, and protection state. |
| 6. Project documentation | Model data, drawings, installation information, and required compliance records | Request documents for the exact model and configuration, especially when an inspector or authority must approve the installation. |
Featured Wall-Mounted 3 Phase Plug Models

DTN5352 / DTN5452 IP67 5-Pole Wall-Mounted Plug
A high-current wall-mounted pin inlet for 400V three-phase circuits that require neutral and protective earth. The IP67 configuration is intended for projects that need a sealed connection when the specified mating and locking conditions are met.
- DTN535263A
- DTN5452125A
- Electrical arrangement5 poles, 3P+N+E
- Rated voltage400V
- Protection levelIP67
- MountingFixed wall-mounted plug / equipment inlet

DTN5342 / DTN5442 IP67 4-Pole Wall-Mounted Plug
A high-current 3P+E wall-mounted pin inlet for three-phase equipment that does not require a neutral conductor. It combines 63A or 125A current classes with an IP67 configuration.
- DTN534263A
- DTN5442125A
- Electrical arrangement4 poles, 3P+E
- Rated voltage400V
- Protection levelIP67
- MountingFixed wall-mounted plug / equipment inlet

DTN5152 / DTN5252 IP67 5-Pole Wall-Mounted Plug
A compact 5-pole wall-mounted inlet for 400V three-phase circuits that need a neutral. Select DTN5152 for the 16A current class or DTN5252 for 32A, then match the cable and mating connector to the same complete configuration.
- DTN515216A; catalog conductor range 1.5–2.5 mm²
- DTN525232A; catalog conductor range 4–6 mm²
- Electrical arrangement5 poles, 3P+N+E
- Rated voltage400V
- Protection levelIP67
- MountingFixed wall-mounted plug / equipment inlet

DTN5142 / DTN5242 IP67 4-Pole Wall-Mounted Plug
A 3P+E wall-mounted inlet for 16A or 32A three-phase equipment without a neutral conductor. The IP67 configuration supports exposed industrial installations when the mating connector, sealing parts, cable entry, and installation state preserve the required protection.
- DTN514216A; catalog conductor range 1.5–2.5 mm²
- DTN524232A; catalog conductor range 4–6 mm²
- Electrical arrangement4 poles, 3P+E
- Rated voltage400V
- Protection levelIP67
- MountingFixed wall-mounted plug / equipment inlet

DTN5351 / DTN5451 IP44 5-Pole Wall-Mounted Plug
A high-current 5-pole wall-mounted inlet for 400V circuits that require three phases, neutral, and protective earth. Its IP44 rating suits installations where the specified splash and solid-object protection is sufficient.
- DTN535163A
- DTN5451125A
- Electrical arrangement5 poles, 3P+N+E
- Rated voltage400V
- Protection levelIP44
- MountingFixed wall-mounted plug / equipment inlet
Choose IP44 or IP67 from the Actual Exposure
IP44 and IP67 describe different ingress-protection test conditions. IP44 is a practical choice where protection against solid objects and splashing water meets the installation requirement. IP67 adds dust-tight protection and protection for temporary immersion under the conditions defined by the applicable test and product instructions.
Use IP67 when the connection may face heavier dust or temporary water exposure and the complete installed connection can maintain that state. IP67 does not automatically cover prolonged submersion, high-pressure washdown, chemical exposure, UV exposure, condensation, mechanical impact, or every outdoor condition.
The completed connection is limited by its components and assembly state. Match the plug with a compatible connector, fit the correct cable entry and seal, close or lock the interface as specified, and install it in an orientation that avoids persistent water loading. If the mating part has a lower protection level, evaluate the connection at the lower or more restrictive condition.
Plan the Plug, Connector, Cable, and Load as One Connection
A wall-mounted plug is the fixed pin side of the connection. Pair it with a compatible female cable connector when power must enter machinery, an enclosure, a distribution assembly, or another fixed installation through a detachable cable.
Mechanical fit is only the first compatibility check. Both sides must match in standard family, rated current size, pole count, voltage, frequency, clock position, keying, pin/socket role, and required ingress-protection state. Two red connectors or two devices with the same ampere rating can still be incompatible.
Use the installation drawing to reserve room for insertion, withdrawal, locking, and cable bend radius. The mounting surface must withstand normal insertion and cable forces without twisting the housing. Keep cable strain off the terminals and use the specified cable entry and sealing parts.
For motor-driven equipment, include phase-sequence requirements in commissioning. A matching connector arrangement does not guarantee the intended direction of rotation until phase sequence is checked at the installed system.
Installation and Pre-Energization Checks
Fixed wall-mounted plugs involve fixed wiring and accessible terminals during installation. A qualified electrical professional should install and verify the connection under the applicable local rules and the instructions for the exact model.
- Isolate every source that can energize the work area, prevent unintended re-energization, and verify absence of voltage with suitable test equipment.
- Confirm the exact model, current, voltage, frequency, pole arrangement, clock position, mating connector, cable range, and environmental requirement.
- Mount the base on a flat, rigid surface without distorting the housing. Preserve the specified entry direction and operating clearance.
- Connect L1, L2, L3, N when required, and protective earth to their marked terminals. Never use neutral as protective earth.
- Use the model-specific conductor preparation, terminal method, stripping length, and tightening torque. Secure the cable so external pull and twist do not reach the terminals.
- Fit the correct cable gland, seals, and blanking parts. Check the cover or locking mechanism and the condition required for the stated IP rating.
- Before energization, verify protective-conductor continuity, insulation, phase sequence where applicable, terminal security, cable restraint, sealing, protection coordination, and functional operation.
Send These Details for an Accurate Quote
Provide one specification for the complete connection so DTCEE can identify the plug, mating connector, and required project documents without relying on a color or product photo alone.
- Site country and applicable electrical or approval requirements
- Supply voltage, frequency, and phase configuration
- Equipment nameplate current or design current, duty, and starting characteristics
- 3P+E or 3P+N+E requirement
- Preferred current class: 16A, 32A, 63A, or 125A
- Required IP level and a description of dust, water, temperature, corrosion, UV, impact, and cleaning exposure
- Wall-mounted inlet location, entry direction, available clearance, and cable routing
- Cable type, conductor material, conductor size, and outside diameter
- Existing plug or connector model, clock position, and clear interface photos when this is a replacement
- Quantity, destination, requested delivery date, and required drawings, test records, or compliance documents