Distribution Board Industrial Socket Panel
The panel format follows the incoming supply, connected load, outlet current, pole count, socket quantity, and portable or fixed mounting required by the actual equipment schedule. Breakers, residual-current protection, earthing, cable entries, and enclosure IP rating work together so every outlet remains protected in its installation environment. A firm quotation requires the outlet schedule, quantity, and delivery destination.
Distribution Board Industrial Socket Panel
Socket Panel Selection by Load and Installation
Product ListThe configuration starts with the incoming voltage, frequency, phase arrangement, maximum simultaneous load, and the cable feeding the panel. Each outlet then receives a rated current, pole configuration, voltage or clock position, branch protective device, and expected duty. Outlet count alone does not increase the incoming capacity.
| Panel format | Best use | Socket and protection plan | Mounting and environment |
|---|---|---|---|
| Portable DT1805–DT1808 boxes | Construction, shutdown maintenance, temporary workshops, and mobile crews | Mixed 16–125 A outlets with project-selected branch protection; IP44 or IP67 configuration | The handled enclosure suits stable work areas, with cable entry and transport duty defined in the order |
| Combined DTZB and DTB boxes | Fixed outlet groups on walls, frames, machinery, or production areas | Outlet schedule and DIN-rail protection arranged in one enclosure; IP65 or IP67 families available | Fixing points, cable-gland direction, service clearance, and the applicable IP state form part of the selected configuration |
| DT75231–DT75126 high-current box | Large machinery, plant feeds, and other 200–400 A connections | 4- or 5-pole switched outlet with mechanical interlock in 200 A, 250 A, or 400 A versions | Surface-mounted coated stainless-steel enclosure for cable sizes up to 65 mm (2.56 in) |
Protection and Enclosure Choices Must Work Together
Product ListThe panel rating, every branch conductor, protective device, and socket outlet must be coordinated as one distribution system. A larger outlet does not increase the capacity of a smaller incoming cable, and multiple connected loads must remain within the verified simultaneous demand of the assembly.
Electrical Protection Based on Fault Risks
An incoming isolator or breaker provides suitable short-circuit capacity, while each outgoing circuit uses an MCB, fuse, RCBO, or coordinated combination sized for its conductors and socket. Residual-current protection applies where the installation rules and connected equipment require it. An MCB alone does not provide earth-leakage protection.
Enclosure Protection for the Actual Exposure
IP44 covers the specified solid-object and splash conditions, IP65 adds dust-tight and water-jet protection, and IP67 covers temporary immersion under its test conditions. The declared protection depends on closed covers, engaged locking rings, intact seals, correct cable glands, and sealed unused openings. It does not by itself prove corrosion, ultraviolet, chemical, impact, or high-pressure-cleaning resistance.
Outlet Schedules Determine Panel Pricing
Product ListDTCEE prices each assembly from the electrical and mechanical scope, not from the box size alone. The required inputs are the incoming supply, maximum simultaneous load, outlet quantity and ratings, voltage or clock positions, branch protection, IP target, mounting method, cable-entry direction, labels, quantity, destination, and applicable standard. A single-line diagram or marked enclosure drawing provides the clearest starting point.
The quotation identifies the supplied outlet and protection schedule, enclosure, wiring, price basis, production time, packing, and shipping term. Standard products typically require 7–15 days; customized or OEM/ODM configurations typically require 20–30 days after the drawing and order details are fixed. High-current interlocked boxes and new tooling follow the custom schedule.
Socket Distribution Panel Families
These DTCEE assemblies combine IEC 60309 socket outlets, enclosure space, and project-selected branch protection in portable, combined, wall-mounted, or high-current formats. Family selection depends on the incoming supply, outlet schedule, environmental exposure, and mounting method.

Removable Portable Socket Distribution Box Series
Portable multi-outlet distribution for construction, maintenance, and temporary industrial power.
- Application / fitPortable site power
- Current / protection16–125 A outlets; IP44/IP67
- MaterialFlame-retardant engineering plastic; brass conductors
- Interface standardIEC 60309 outlets; EN 60439-4 assembly
Paid 1-unit configuration sample; typical 7–15 days

Portable Industrial Socket Box Series
Portable enclosure with a protected DIN-rail section and configurable outlet schedule.
- Application / fitWorkshops and temporary distribution
- Current / protection16–125 A outlets; IP44/IP67
- MaterialFlame-retardant engineering plastic; brass conductors
- Interface standardIEC 60309-2; DIN VDE 0623
Paid 1-unit configuration sample; typical 7–15 days

Combined Socket Distribution Box Series
Combined socket and breaker layout for wall, frame, or equipment-side installation.
- Application / fitFixed protected outlet groups
- Current / protection16–125 A outlets; IP65/IP67
- MaterialEngineering-plastic enclosure; brass conductors
- Interface standardEN 60309 industrial outlets
Paid 1-unit configuration sample; typical 15–20 days

IP67 Three-Outlet Socket Box Series
IP67 enclosure platform for a three-outlet industrial distribution arrangement.
- Application / fitDusty or wet industrial locations
- Current / protection16–125 A outlets; IP67
- MaterialFlame-retardant engineering-plastic enclosure
- Interface standardEN 60309 outlet openings
Paid 1-unit configuration sample; typical 15–20 days

IP67 Protected Distribution Box Series
IP67 wall enclosure with space for branch protection and a project-specific socket layout.
- Application / fitWall-mounted industrial distribution
- Current / protection16–125 A outlets; IP67
- MaterialFlame-retardant engineering-plastic enclosure
- Interface standardEN 60309 outlets and DIN-rail protection
Paid 1-unit configuration sample; typical 15–20 days

High-Current Surface-Mounted Outlet Box
Switched, mechanically interlocked outlet box for 200 A to 400 A high-current connections.
- Application / fitHigh-current machinery and shore or plant feeds
- Current / protection200/250/400 A; 4 or 5 poles
- MaterialRAL 1021 coated stainless-steel enclosure
- Interface standardSwitched mechanical interlock; IP55 box
Engineering sample by quotation; typical 20–30 days
Ordering and Delivery
Prices are based on the complete outlet, protection, enclosure, quantity, and delivery scope.
1 unit; charged to the selected socket, protection, and enclosure schedule; typical 7–15 days for standard builds.
10–49 units; made to order; unit price based on outlet mix and protection devices; typical 15–20 days.
50+ units; volume pricing after approved drawing; typical 20–30 days for customized builds.
Standard configurations typically ship in 7–15 days; OEM/ODM configurations typically require 20–30 days.
Courier, air, or sea shipment with export packing; EXW, FOB, or CIF quoted by destination and order size.
Commercial invoice, packing list, approved outline or outlet-schedule drawing, and inspection record for the ordered configuration.
Upload the Panel Drawing or Outlet Schedule
Upload a single-line diagram, outlet schedule, or marked enclosure drawing together with the required quantity and work email. DTCEE uses the file to define the incoming supply, socket ratings, pole count, protection devices, cable entries, labels, and mounting arrangement before quotation.
Questions About Socket Panel Orders
These answers cover configuration details that affect the supplied assembly.
Can one panel contain outlets for different voltages?
Yes, when each outlet has the correct IEC 60309 voltage and clock-position configuration, clear labeling, a dedicated correctly rated branch circuit, and protection matched to that circuit. Different systems must not share an ambiguous or unverified connection path.
Does IP67 apply while every socket is open?
IP67 applies only in the product states covered by the selected configuration. Covers, seals, cable glands, unused-opening plugs, mating connectors, and locking rings must all be in their specified positions; IP67 does not mean permanent submersion or high-pressure washdown.
Can the panel arrive wired and ready for installation?
DTCEE can quote an assembled panel with the agreed incoming device, branch protection, socket schedule, internal wiring, labels, and enclosure. The order drawing defines the supplied scope so installers can plan the upstream cable, earthing, mounting, and site tests separately.
When does the high-current outlet box fit the project?
The DT75231–DT75126 family fits projects that need a switched, mechanically interlocked 200 A, 250 A, or 400 A outlet in a 4- or 5-pole configuration. It is a separate high-current assembly, not a substitute for adding more low-current outlets.
Which approval documents can accompany the order?
A confirmed order can include the commercial invoice, packing list, approved outline or outlet-schedule drawing, and an inspection record for the ordered configuration. Product or conformity documents are supplied only when their model and scope cover the exact items ordered.
Request a Socket Panel Quotation
Send the incoming supply, outlet schedule, protection requirements, enclosure or IP target, mounting method, quantity, and destination.
- Phone: +86 13336970867
- Email: info@dtcee.com
- WhatsApp: +86 13336970867
- Henghe Industrial Zone, Panshi Town, Yueqing City, Zhejiang Province, China
DTCEE