Industrial Multiple Socket Outlet
An industrial multiple socket outlet distributes one protected power supply to several industrial connectors in a rugged portable or enclosed assembly. Selection depends on the incoming voltage and phase, total simultaneous load, outlet current and pole configuration, upstream protection, and the site’s dust and water exposure—not on outlet count alone.
Industrial Multiple Socket Outlet
One Supply, Several Protected Industrial Outlets
Product ListAn industrial multiple socket outlet is a distribution assembly, not a domestic convenience strip. It places several industrial socket outlets in a portable unit or protected enclosure so tools, machines, lighting, or service equipment can connect to one planned supply point.
Portable and removable units suit construction areas, maintenance work and temporary events where the power point moves with the job. Combined socket boxes place different outlet arrangements and optional protective devices in one enclosure. Enclosed distribution boxes suit fixed locations or project-specific layouts where cable entry, mounting and outlet positions must follow the installation.
More outlets do not create more available power. Add the loads that can run at the same time and keep that total within the inlet, internal conductors and upstream protective device. A qualified electrical designer should confirm conductor sizing, protective-device coordination and local installation requirements.
Supply, Load, Connector, and IP Compatibility
Product ListThe available supply establishes the voltage, phase, frequency and maximum current. The inlet and each outlet must use the correct current rating, pole arrangement, color code and earth clock position for the plugs already used on site. IEC 60309 connectors prevent many mismatches mechanically, but a similar-looking connector is not proof of electrical compatibility.
Total simultaneous demand includes loads that operate together, motor starting current and other short-duration demand. The assembly rating, feeder, breaker and residual-current protection must work as one system. Individual outlet isolation or overload protection can be defined in the distribution-box layout when required.
IP44 suits locations where splash protection is sufficient. IP65 applies where a listed complete enclosure must resist dust and water jets, while IP67 applies where the complete closed assembly needs dust-tight construction and protection during temporary immersion. The final IP rating applies only when covers, cable entries and mating connectors are installed and closed as specified.
Complete Distribution Assembly Specifications
Product ListAn accurate configuration includes the supply voltage, phase, frequency and maximum current; the number and type of outlets; the current, pole and earth-position code for each connector; and the loads expected to run together. Other inputs include mounting method, cable-entry direction, required protective devices, operating environment, quantity and target standard.
DTCEE supplies portable, removable, combined and enclosed socket distribution boxes. The selected families cover EN 60309, IEC 60309-2, DIN VDE 0623 and EN 60439-4 applications with stated protection options from IP44 through IP67, depending on the family and configuration. Enclosure layout, outlet mix, marking, cable entry and packaging can be reviewed for OEM or ODM orders.
Standard configurations typically require 7–15 days after order details are confirmed. OEM or ODM configurations typically require 20–30 days, depending on engineering changes and tooling. Final lead time and packing terms depend on the approved configuration and order quantity.
DTCEE Industrial Socket Distribution Box Families
DTCEE supplies portable, removable, combined, and enclosed socket distribution boxes that place multiple industrial outlets in one protected assembly. The four families below cover mobile site power, compact portable distribution, mixed-outlet combinations, and enclosed project-specific layouts. Their differences include mounting and mobility, outlet mix, applicable product standard, and IP44, IP65, or IP67 environmental protection.

Removable Industrial Socket Boxes Portable Socket Distribution Boxes – Industrial Multiple Socket Outlet
Portable site and temporary power distribution. Models: DT1806 / DT1807 / DT1808.
- Application / fitPortable site and temporary power distribution
- Current / protection16A / 32A configurations; IP44 / IP67
- Enclosure / conductorsFlame-retardant engineering plastic / brass
- Interface standardEN 60439-4; IEC 60529

Industrial Socket Boxes Portable Socket Distribution Boxes – Industrial Multiple Socket Outlet
Compact portable distribution for service and workshop loads. Models: DT1805 / DT1805B / DT1805C.
- Application / fitCompact portable distribution for service and workshop loads
- Current / protection16A / 32A configurations; IP44 / IP67
- Enclosure / conductorsFlame-retardant engineering plastic / brass
- Interface standardDIN VDE 0623 / IEC 60309-2; IEC 60529

Industrial Socket Boxes Combined Socket Distribution Boxes – Industrial Multiple Socket Outlet
Combined outlet layouts for dusty, wet, or fixed project areas. Models: DTZB1601 / DTZB1602 / DTZB1603 / DTZB1604.
- Application / fitCombined outlet layouts for dusty, wet, or fixed project areas
- Current / protection16A / 32A configurations; IP65 / IP67
- Enclosure / conductorsFlame-retardant engineering plastic / brass
- Interface standardEN 60309; IEC 60529

Innovation Industrial Socket Boxes Distribution Boxes – Industrial Multiple Socket Outlet
Enclosed project distribution where maximum ingress protection is required. Models: DTB334317 / DTB334317-2 / DTB335317.
- Application / fitEnclosed project distribution where maximum ingress protection is required
- Current / protection16A / 32A configurations; IP67
- Enclosure / conductorsFlame-retardant engineering plastic / brass
- Interface standardEN 60309; IEC 60529
Samples, Production, and Delivery
Lead time starts after the electrical configuration, enclosure layout, marking and packing are approved.
MOQ 1 unit. Sample pricing follows the approved outlet layout; standard configurations target dispatch in 7–15 days.
10–49 units with quantity-based quotation, visual and electrical inspection, and agreed packing. Standard production target: 7–15 days.
50+ units with negotiated pricing, a confirmed production slot and an agreed replenishment schedule.
Standard configurations typically require 7–15 days. OEM or ODM configurations typically require 20–30 days after approval.
EXW, FOB, CIF, express, air or sea freight can be selected according to destination, shipment size and buyer instructions.
Commercial invoice, packing list and inspection records are supplied. Applicable compliance documents follow the ordered model and destination.
Send the Electrical Layout and Site Conditions
Upload a drawing, single-line diagram, outlet schedule, or marked reference image. Include supply voltage and phase, total current, outlet types and quantities, protective devices, mounting, cable entry, IP rating, quantity, and any marking or packaging requirements.
Industrial Multiple Socket Outlet Questions
These answers summarize the electrical and environmental information needed for selection.
Does the number of outlets determine the available power?
No. Available power is limited by the incoming supply, inlet, conductors, enclosure components and upstream protective device. Add the loads that can operate at the same time, including motor starting demand, before choosing the assembly rating.
Which IP rating should I specify?
IP44 suits locations where splash protection is sufficient. IP65 applies to a listed dust-tight enclosure exposed to water jets, while IP67 applies where the complete closed assembly requires dust-tight construction and temporary-immersion protection. Covers, glands and mating plugs must preserve the stated rating.
Will the outlets fit our existing industrial plugs?
Compatibility depends on matching voltage, frequency, current, pole arrangement, color code and earth clock position for every connector. IEC 60309 keying reduces accidental mismatch, but the complete electrical specification must still match the site supply and connected equipment.
Can the box include breakers or residual-current protection?
Protective devices can be specified in a combined or enclosed distribution layout. Coordination requires the feeder rating, required outlet circuits and site protection rules so the breaker and RCD arrangement works with the upstream system.
What information is needed for a custom socket box?
A complete request includes the supply voltage, phase, frequency and maximum current; outlet types and quantities; connected loads; mounting and cable-entry requirements; IP rating; protective devices; quantity; target standard; and any drawing, labeling or packaging requirements.
Configure Your Industrial Socket Distribution Box
Send the supply, load, connector, environment and quantity requirements for a model recommendation and quotation.
- Phone: +86 13336970867
- Email: info@dtcee.com
- WhatsApp: +86 13336970867
- Henghe Industrial Zone, Panshi Town, Yueqing City, Zhejiang Province, China
DTCEE