industrial type connector
IEC 60309 Industrial Power Connections
Specify a dependable power connection for machinery, temporary distribution, factory equipment, and demanding outdoor installations. DTCEE supplies IEC 60309 plugs, sockets, couplers, equipment inlets, and distribution solutions across standard 16A–125A ratings, plus high-current 200A, 250A, and 400A options.
Choose by electrical configuration, connection format, installation method, and required ingress protection. Browse the featured range or send DTCEE a project brief for a matched model recommendation and quote.
DTCEE IP67 industrial coupler for secure industrial power connections.
Choose the Connector Format First
An industrial type connector can refer to many power, signal, and data interfaces. This page covers DTCEE’s IEC 60309 industrial power connection range: plugs, socket-outlets, couplers, equipment inlets, and related distribution products for industrial electrical systems.
Start with the job each end of the connection must perform. A cable-mounted plug provides the pin side on a flexible cable. A portable socket-outlet, often sold as an industrial coupler, provides the socket-contact side on a flexible cable. Fixed socket-outlets create power outlets on walls, panels, or enclosures, while appliance inlets provide a pin-side input on equipment or a fixed structure.
| Connection requirement | Product format to evaluate | Typical installation role |
|---|---|---|
| Feed movable equipment from a flexible cable | Industrial plug plus portable socket-outlet/coupler | Extension leads, temporary power, movable machinery |
| Provide a fixed industrial power outlet | Wall-mounted or panel-mounted socket-outlet | Factory walls, enclosures, distribution points |
| Bring power into equipment | Wall-mounted or panel-mounted appliance inlet | Machinery, control cabinets, production equipment |
| Distribute several protected outputs | Industrial socket box or distribution box | Work areas, construction power, maintenance stations |
| Carry high current through a detachable connection | High-current plug, socket, or coupler | Large equipment and high-load distribution systems |
DTCEE’s catalog includes A, B, and C product series with IP44 and IP67 configurations. Standard current ratings include 16A, 32A, 63A, and 125A. A separate high-current family covers 200A, 250A, and 400A connections in four- and five-pole configurations.
Discuss Your Connection LayoutMatch Every Electrical and Environmental Parameter
A compatible connector is defined by its complete electrical, mechanical, and environmental specification. Confirm the connection task first, then match the electrical configuration, mechanical keying, protection level, mounting arrangement, and cable interface.
| Selection item | What to confirm | Why it changes the choice |
|---|---|---|
| Connector role | Plug, portable socket-outlet/coupler, fixed socket-outlet, or appliance inlet | Determines whether the end has pins or socket contacts and whether it moves with a cable or mounts to equipment |
| Rated current | Equipment nameplate current or engineered design current, duty, upstream protection, and conductor capacity | Prevents the connector rating from being selected independently of the cable and protected circuit |
| Voltage and frequency | Actual supply system and equipment input requirements | Determines the applicable IEC 60309 configuration and prevents connection to the wrong supply |
| Pole configuration | Required phase, neutral, and protective-conductor arrangement | Separates circuits that need a neutral from those that do not |
| Clock position and keying | Protective-contact position and the matching configuration at both ends | Prevents incompatible voltage, frequency, or application configurations from mating |
| Ingress protection | Exposure to dust, splashing, water jets, temporary immersion, condensation, and the connected operating state | Establishes the required enclosure and sealing performance |
| Installation | Cable-mounted, wall-mounted, panel-mounted, straight, or angled; required working clearance | Affects mounting dimensions, cable entry, operation, and enclosure integrity |
| Cable and terminals | Cable outside diameter, conductor size, core count, sheath, and strain relief | Ensures the cable entry, seal, clamp, and terminals work as one assembly |
| Compliance documents | Destination market, project specification, applicable standard, and required records | Defines which declarations, certificates, reports, and labels must accompany the order |
Featured Industrial Connector Options

DTN2342/DTN2442 400V industrial coupler in 63A and 125A configurations.
DTN2342/DTN2442 4-Pole IP67 Industrial Coupler
This cable-mounted coupler provides a four-pole, 400V connection for 63A or 125A industrial power circuits. Its IP67 construction, nylon PA housing, and nickel-plated brass conductors support demanding cable-to-cable and cable-to-equipment connection tasks. The listed operating-temperature range is -30°C to 50°C (-22°F to 122°F), and the product specification lists 5,000 mating cycles.
- ModelsDTN2342 / DTN2442
- Rated current63A / 125A
- Rated voltage400V
- Pole configuration4 poles
- Protection levelIP67
- HousingNylon PA
- ConductorsNickel-plated brass

DTN2332/DTN2432 three-pole coupler for 230V industrial connection requirements.
DTN2332/DTN2432 3-Pole IP67 Industrial Coupler
The DTN2332/DTN2432 family provides a three-pole, 230V cable-mounted connection at 63A or 125A. An IP67 enclosure supports dusty and wet industrial environments when the specified mating, sealing, and installation conditions are met. The listed materials are a nylon PA housing with nickel-plated brass conductors, and the operating-temperature range is -30°C to 50°C (-22°F to 122°F).
- ModelsDTN2332 / DTN2432
- Rated current63A / 125A
- Rated voltage230V
- Pole configuration3 poles
- Protection levelIP67
- HousingNylon PA
- ConductorsNickel-plated brass

High-current DT Series couplers for 200A, 250A, and 400A industrial power connections.
DT Series High-Current IP67 Industrial Couplers
DT Series high-current couplers create detachable industrial power connections at 200A, 250A, or 400A. Four- and five-pole versions are available, with model pairs for each current class. The products are rated IP67, and the product specification lists a control-signal contact. The listed operating-temperature range is -30°C to 50°C (-22°F to 122°F).
- 200A modelsDT75211 / DT75216
- 250A modelsDT75011 / DT75101
- 400A modelsDT75016 / DT75106
- Pole configurations4 poles / 5 poles
- Protection levelIP67
- Listed mating cycles5,000
- Additional featurecontrol-signal contact

DTN2352/DTN2452 five-pole 400V coupler in 63A and 125A configurations.
DTN2352/DTN2452 5-Pole IP67 Industrial Coupler
This five-pole, 400V coupler family is available in 63A and 125A ratings for circuits that require five contacts. The cable-mounted design uses a nylon PA housing and nickel-plated brass conductors. Its IP67 rating supports installations that require dust-tight construction and protection against temporary immersion under the rated test conditions.
- ModelsDTN2352 / DTN2452
- Rated current63A / 125A
- Rated voltage400V
- Pole configuration5 poles
- Protection levelIP67
- Operating temperature-30°C to 50°C (-22°F to 122°F)
- Listed mating cycles5,000
Application Conditions That Change the Specification
Motors, Welders, and Cyclic Loads
Motor starting current, welder duty cycles, transformer inrush, and other intermittent loads can exceed normal operating current for short periods. Use equipment nameplate data and the engineered circuit design to coordinate the connector, cable, and protective device instead of selecting the connector from running power alone.
Panel and Enclosure Integration
Panel cutout, flange size, fixing-hole pattern, rear depth, operating clearance, and cable-entry direction are specific to each mounted model. The equipment designer should place the selected model’s drawing into the enclosure layout and specify the gasket and fasteners that maintain the enclosure’s target protection.
Portable and Temporary Distribution
Extension leads and portable distribution equipment place repeated bending, pulling, dragging, and impact loads on the cable assembly. Select the cable sheath, entry seal, clamp, and bend space for that movement, and ensure the strain-relief system keeps force away from the terminals. Multi-outlet distribution equipment also requires branch protection and an input rating based on the planned simultaneous load, not a simple sum of outlet ratings.
Outdoor and Wet Locations
Rain, wash water, condensation, temperature, sunlight, and airborne chemicals affect different parts of the connection. Water exposure determines the required IP test condition; sunlight, chemicals, and temperature can change the housing and seal material requirement. Mounting orientation and drainage must keep water from collecting around the cable entry or enclosure interface.
IEC 60309 Keying and IP Protection
IEC 60309 uses color as a quick voltage-range indicator and uses the protective-contact clock position and mechanical keying to prevent incompatible configurations from mating. The purchaser should confirm the clock position from the product marking or model data sheet; appearance and color alone cannot establish a mating pair.
DTCEE product documentation covers industrial plugs, socket-outlets, and couplers in configurations that reference EN IEC 60309-1 and EN IEC 60309-2. When responding to an inquiry, DTCEE can identify the declarations, certificates, or test records available for the exact model and destination market.
IP ratings describe tested protection against solid objects and water under defined conditions. IP44 addresses entry by solid objects larger than the specified probe and splashing water. IP67 indicates dust-tight construction and protection against temporary immersion under the applicable test conditions. For wet locations, state whether protection is required while the connector is mated, unplugged, or closed with its cover so DTCEE can evaluate the complete plug, socket, seal, and cable-entry arrangement.
Confirm Standards and ProtectionBuild a Quote-Ready Connector Specification
DTCEE is the product brand of Yueqing Datong Electrical Co., Ltd., a manufacturer whose documented business scope includes the production and sale of industrial plugs, socket-outlets, and appliance couplers. The product range supports standard model selection as well as OEM and ODM discussions for defined project requirements.
Send one complete specification for each connection point:
- Connector role: plug, portable socket-outlet/coupler, fixed socket-outlet, or appliance inlet
- Electrical system: voltage, frequency, phase arrangement, design current, and upstream protection
- Pole configuration: required phase, neutral, and protective-conductor arrangement
- Mating interface: clock position, color, existing mating model, or clear label photographs
- Environment: required IP state, temperature, water, dust, chemicals, impact, and indoor or outdoor use
- Installation: cable-mounted, wall-mounted, panel-mounted, straight, or angled
- Cable: conductor size, number of cores, outside diameter, sheath type, and required entry direction
- Order: quantity, sample or production order, packaging, labeling, logo, and required documents
- Delivery: destination, requested shipping date, and preferred Incoterms® rule with the named place
The final price depends on the selected electrical configuration, current class, pole count, protection level, materials, mounting format, quantity, customization, documentation, packaging, and delivery terms. A useful quotation should identify the exact model, quantity, unit price, currency, included accessories and documents, packaging, lead time, quote validity, and shipping basis.
Request a Configuration-Based QuoteFrequently Asked Questions
Can DTCEE customize an industrial connector order?
DTCEE accepts OEM and ODM discussions for requirements such as housing color, logo marking, packaging, cable specifications, and structural details. Changes that affect ratings, keying, safety, or compliance require engineering review and confirmation of the applicable documentation before production.
What should I provide when replacing an existing connector?
Send the existing product’s manufacturer, model, full nameplate, front interface, clock position, cable entry, and mounting dimensions. Add the equipment wiring diagram or circuit requirements when available. DTCEE can then compare the existing interface and circuit requirements with a specific replacement.
What lead time should I plan for?
DTCEE lists a typical lead time of 7–15 days for standard products and 20–30 days for OEM, ODM, or customized products. Quantity, tooling, approval steps, material availability, and the production schedule can change the order date, so the confirmed quotation should state when lead time begins and the planned shipment date.
Tell Us Your Industrial Connector Requirements
Use the form to request model selection, pricing, samples, or an OEM/ODM discussion.
- Phone: +86 13336970867
- Email: info@dtcee.com
- WhatsApp: +86 13336970867
- Address: Henghe Industrial Zone, Panshi Town, Yueqing City, Zhejiang Province,China
DTCEE