Search the whole station

ip67 waterproof industrial plug and socket

DTCEE supplies IP67 industrial power plugs and a wall-mounted socket for 230V and 400V connections. Compare 16A, 32A, 63A, and 125A options with 3-, 4-, or 5-contact configurations, then send us the electrical and installation details needed to match the correct interface.

Compare the IP67 range by current, voltage, and pole count

The five products below cover cable-mount industrial plugs and a fixed wall-mounted socket. Start with the connection role, then narrow the range by current, voltage, and the number and function of the contacts.

Model familyProduct formRated currentRated voltagePins / polesIP ratingListed ambient range
DTN0332 / DTN0432Cable-mount industrial plug63A / 125A230V3 pinsIP67-22°F to 122°F (-30°C to 50°C)
DTN0152 / DTN0252Cable-mount industrial plug16A / 32A400V5 pinsIP67-22°F to 122°F (-30°C to 50°C)
DTN0142 / DTN0242Cable-mount industrial plug16A / 32A400V4 pinsIP67-22°F to 122°F (-30°C to 50°C)
DTN0132 / DTN0232Cable-mount industrial plug16A / 32A230V3 pinsIP67-22°F to 122°F (-30°C to 50°C)
DTN1352 / DTN1452Wall-mounted industrial socket63A / 125A400V5 polesIP67-22°F to 122°F (-30°C to 50°C)
View the Five Product Options

Choose the complete electrical interface—not color alone

An industrial plug and socket must match as a complete electrical and mechanical interface. Use this sequence to identify the required configuration.

  1. Define each end of the connection. Select a plug when the cable end needs pins. Select a fixed socket when fixed wiring needs a socket-contact outlet. Confirm the required mating product at the same time.
  2. Confirm the power system. Record rated voltage, frequency, single-phase or three-phase supply, and whether the circuit requires a neutral conductor.
  3. Specify the complete contact arrangement. A visible count of three, four, or five contacts does not by itself identify phase, neutral, and protective-earth functions. State the required pole arrangement from the equipment nameplate and circuit design.
  4. Coordinate the current rating. Choose 16A, 32A, 63A, or 125A against the design current, cable ampacity, terminal range, duty, and upstream protection.
  5. Match the keying details. Confirm the standard series, rated voltage, frequency, protective-earth clock position, contact layout, and the exact mating model. Similar color and shape do not prove compatibility.
  6. Check the installation and environment. Identify cable-mount or wall-mount construction, cable size, entry direction, operating space, exposure to dust or water, temperature, and the IP67 state required in service.

Blue and red inserts can help identify common voltage ranges, but the product marking and full interface data control the selection. Send a front-facing interface photo and the existing product model when replacing an installed accessory.

Send Your Connection Requirements

IP67 industrial plugs and wall-mounted socket

Blue three-pin DTN0332/DTN0432 industrial plug with gray locking collar and rear cable entry

Cable-mount 230V industrial plug offered in 63A and 125A versions.

Industrial Plug DTN0332 DTN0432 With Dust And Water Resistance

This blue three-pin industrial plug provides a cable-end option for 230V applications requiring either a 63A or 125A accessory. Its listed construction combines a nylon PA shell with nickel-plated brass conductors, and DTCEE states 5,000 mating cycles for this model family.

  • ModelsDTN0332 / DTN0432
  • Rated current63A / 125A
  • Rated voltage230V
  • Contact count3 pins
  • Ingress protectionIP67
  • Conductorsnickel-plated brass
  • Shellnylon PA
  • Listed ambient temperature-22°F to 122°F (-30°C to 50°C)
Red five-pin DTN0152/DTN0252 industrial plug with gray locking collar and rear cable entry

Cable-mount 400V industrial plug offered in 16A and 32A versions.

High Protective Industrial Plug DTN0152 DTN0252

This red five-pin industrial plug covers 400V connections at 16A or 32A. The nylon PA shell and nickel-plated brass conductors are paired with catalog conductor sizes of 1.5–2.5 mm² for DTN0152 and 4–6 mm² for DTN0252.

  • ModelsDTN0152 / DTN0252
  • Rated current16A / 32A
  • Rated voltage400V
  • Contact count5 pins
  • Ingress protectionIP67
  • Catalog conductor size1.5–2.5 mm² / 4–6 mm²
  • Conductorsnickel-plated brass
  • Shellnylon PA
  • Listed ambient temperature-22°F to 122°F (-30°C to 50°C)
Red four-pin DTN0142/DTN0242 industrial plug with gray locking collar and rear cable entry

Four-pin 400V industrial plug offered in 16A and 32A versions.

Waterproof Industrial Plug DTN0142 DTN0242

This red four-pin industrial plug provides a 400V cable-end connection in 16A and 32A versions. Its listed materials are a nylon PA shell and nickel-plated brass conductors, with conductor ranges sized to the selected current model.

  • ModelsDTN0142 / DTN0242
  • Rated current16A / 32A
  • Rated voltage400V
  • Contact count4 pins
  • Ingress protectionIP67
  • Catalog conductor size1.5–2.5 mm² / 4–6 mm²
  • Conductorsnickel-plated brass
  • Shellnylon PA
  • Listed ambient temperature-22°F to 122°F (-30°C to 50°C)
Blue three-pin DTN0132/DTN0232 industrial plug with gray locking collar and rear cable entry

Three-pin 230V industrial plug offered in 16A and 32A versions.

DTN0132 DTN0232 IP67 Waterproof Industrial Plugs for Charging Pile

This blue three-pin industrial plug covers 230V cable-end connections at 16A or 32A. The listed construction uses a nylon PA shell and nickel-plated brass conductors, with separate catalog conductor ranges for the two current ratings.

  • ModelsDTN0132 / DTN0232
  • Rated current16A / 32A
  • Rated voltage230V
  • Contact count3 pins
  • Ingress protectionIP67
  • Catalog conductor size1.5–2.5 mm² / 4–6 mm²
  • Conductorsnickel-plated brass
  • Shellnylon PA
  • Listed ambient temperature-22°F to 122°F (-30°C to 50°C)
White DTN1352/DTN1452 wall-mounted socket with red five-pole insert and open protective cover

Fixed 400V industrial socket offered in 63A and 125A versions.

High Quality Industrial Wall Mounted Socket DTN1352 DTN1452

This fixed wall-mounted socket provides a five-pole 400V outlet in 63A or 125A versions. The enclosure includes a hinged protective cover, while the listed product materials include a nylon PA shell and nickel-plated brass conductors.

  • ModelsDTN1352 / DTN1452
  • Product formwall-mounted socket
  • Rated current63A / 125A
  • Rated voltage400V
  • Contact count5 poles
  • Ingress protectionIP67
  • Conductorsnickel-plated brass
  • Shellnylon PA
  • Listed ambient temperature-22°F to 122°F (-30°C to 50°C)

Match IP67 to the actual exposure

IP67 describes protection against dust ingress and temporary immersion under the specified test conditions. It supports selection for locations where dust and water entry are material concerns, provided the complete installation maintains the required sealing state.

Site conditionWhat to verify
Dust exposureConfirm the assembled product, cable entry, unused openings, and mating interface maintain the specified closed or connected state. Damaged seals or incomplete closure can reduce protection.
Temporary immersion riskConfirm the product’s IP67 conditions, installation orientation, cover or locking position, seals, and drainage around the installation.
Water jets or high-pressure washdownObtain the required jet or washdown rating separately; the “7” in IP67 does not by itself establish water-jet performance.
Outdoor exposureCheck ultraviolet exposure, condensation, temperature, corrosion, impact, cable loading, and drainage in addition to the IP code.
Long-term submersionSelect a product and installation specifically rated for that condition; IP67 describes temporary immersion, not continuous underwater service.
Hazardous locationVerify the applicable hazardous-location classification and approvals separately; IP67 is not an explosion-protection rating.
Discuss Your Installation Environment

Materials and connection design

The cable-mount plugs use a straight body with a front locking collar and rear cable entry. The cable diameter, conductor count, conductor cross-section, gland, and strain-relief arrangement must work together so external pulling or twisting does not load the terminals.

The DTN1352/DTN1452 socket places the contact interface in a wall-mounted enclosure with a hinged cover. Installation planning should account for the supporting surface, cable entry, wiring space, cover travel, plug insertion and removal, locking movement, and the direction of cable loading.

For frequent connection cycles, include the expected mating frequency in the inquiry. The DTN0332/DTN0432 source page states 5,000 mating cycles; service life for the other listed products should be confirmed against the selected model and operating conditions.

Plan installation and service conditions before wiring

Qualified electrical personnel should install fixed-wiring accessories and complete the cable termination in accordance with the exact product instructions and applicable local rules. Isolate the supply, prevent unintended re-energization, and verify the work area is de-energized before accessing conductors.

Before installation, compare the product marking and mating accessory against the design: current, voltage, frequency, pole arrangement, protective-earth clock position, terminal capacity, IP67 state, and environmental conditions. Use the selected model’s dimensional drawing or mounting template rather than dimensions from a similar current or pole version.

Match conductor size and cable diameter to the terminal and cable-entry ranges. For the listed 16A plug models, the catalog conductor range is 1.5–2.5 mm²; for the listed 32A plug models, it is 4–6 mm². Cable ampacity, voltage drop, routing, ambient conditions, and upstream protection also affect the final conductor choice.

After wiring, verify terminal tightening, protective-earth continuity, cable strain relief, gland compression, seals, unused-entry closures, cover movement, locking action, and product labeling. Complete the electrical checks required for the circuit before energizing it.

During service, stop using the connection if the enclosure cracks, the interface becomes loose, the contacts show overheating or arcing, a seal fails, the lock no longer holds, or water enters the enclosure. Replace damaged sealing or locking parts with components approved for the exact product.

Ask for Model-Specific Installation Data

Send a complete RFQ for an accurate match

A complete request lets DTCEE identify the electrical interface and quote comparable product, accessory, documentation, and delivery items. Include the following information:

  • Required product role: cable-mount plug, wall-mounted socket, or a matched plug-and-socket set
  • Exact quantity for each item
  • Rated current and rated voltage
  • Frequency and single-phase or three-phase supply
  • Complete pole arrangement, including neutral and protective earth where required
  • Protective-earth clock position and existing mating model, if the connection must fit installed equipment
  • Cable type, outer diameter, conductor count, and conductor cross-section
  • Indoor or outdoor location, ambient temperature, dust and water exposure, and required connected or closed IP state
  • Mounting surface, entry direction, available space, and dimensional constraints for a fixed socket
  • Required drawings, data sheets, test or compliance documents, labels, packaging, and destination market
  • Ship-to city and country, requested quantity breaks, target delivery date, and preferred trade term

Ask the quotation to identify the exact model, quantity, unit price, currency, included accessories, documents, packaging, estimated dispatch time, shipping basis, payment terms, and quote validity. Any proposed substitute should list the differences in interface, rating, dimensions, materials, and applicable documentation.

Build Your RFQ

IP67 plug and socket FAQ

What should I provide for a U.S. project?

Provide the installation location, supply system, equipment rating, required listing or approval, and the authority having jurisdiction’s requirements. Product color or an IEC-style interface does not establish compliance with a U.S. project specification.

Get a Configuration Check

Request an IP67 Plug or Socket Quote

Tell us the electrical configuration, installation form, cable details, environment, quantity, and destination. If you are matching an installed connector, include the existing model and clear photos of the marking and contact face.

  • Phone: +86 13336970867
  • Email: info@dtcee.com
  • WhatsApp: +86 13336970867
  • Address: Henghe Industrial Zone, Panshi Town, Yueqing City, Zhejiang Province,China

DTCEE will use the information you provide to review the requested configuration and respond to your inquiry.