DTCEE DT514 and DT524 are red, four-pole wall-mounted plugs for fixed 380-415 V three-phase equipment inlets. Choose the 16 A DT514 or 32 A DT524 to match the circuit, cable and female connector. The IP44 housing combines a fixed mounting base, protected wiring chamber and 6h keyed interface.

  • Rated Current16 A (DT514) Or 32 A (DT524)
  • Rated Voltage380-415 V AC, 50/60 Hz
  • Pole Configuration4-Pole, 3P+E, 6h
  • Ingress ProtectionIP44
  • Mounting Width70 mm
  • Conductor Range1-2.5 mm² Or 2.5-6 mm²

CURRENT AND CABLE SELECTION

Choose DT514 Or DT524 For The Circuit, Not By Enclosure Color Alone

Both models use the red 400 V, four-pole 6h interface. The current size and conductor range determine the correct variant and mating connector.

Decision PointDT514DT524
Rated Current16 A32 A
Conductor Range1-2.5 mm²2.5-6 mm²
Best FitCompact equipment and branch circuits designed for 16 A accessoriesHigher-current machinery circuits with 32 A cable, protection and mating connectors
TradeoffSmaller current size and cable rangeHigher circuit capacity with larger conductors and a different current-size interface
Selection RecommendationSelect DT514 when the designed load current and conductor size remain within the 16 A circuit. Select DT524 only when the entire circuit, protection, cable and mating connector are rated for 32 A. The two current sizes are not interchangeable even when both are red, four-pole and 6h.

COMPLETE SPECIFICATIONS

Red Wall Mounted Plug Specifications

Use the current rating, conductor range, pole layout and 6h position together when matching the inlet to its circuit and female connector.

Product NameRed Wall Mounted Plug
Models And Rated CurrentDT514: 16 A; DT524: 32 A
Product CategoryA-Series IP44 Wall-Mounted Plug
Rated Voltage And Frequency380-415 V AC, 50/60 Hz
Pole Configuration4-pole, 3P+E, red, 6h
Conductor RangeDT514: 1-2.5 mm²; DT524: 2.5-6 mm²
Mounting Dimensions70 mm enclosure width; 57.5 mm mounting-center pitch; four Ø5 mm fixing holes; Ø20 mm cable entry
General Dimensional Tolerance±0.5 mm for molded-enclosure dimensions unless specifically controlled on the drawing
MaterialsFlame-retardant engineering thermoplastic housing with solid brass current-carrying pins
Ingress ProtectionIP44 when correctly installed and mated
Applicable StandardsEN IEC 60309-1:2022 and EN IEC 60309-2:2022
Marking And PackingProduct rating and model identification; individually protected units grouped in labeled export cartons

APPLICATIONS & EQUIPMENT

Fixed Three-Phase Equipment Inlet Applications

The male wall-mounted interface connects a fixed equipment or enclosure inlet to a matching cable-mounted female connector.

01

Machine And Control-Cabinet Power Inlets

Use on machinery, control cabinets or surface-mounted enclosures that receive a matching 4-pole 6h female connector.

02

Three-Phase Production Equipment

Choose DT514 or DT524 according to the designed load current, cable size, protective device and matching connector.

03

Workshop And Sheltered Outdoor Installations

IP44 supports locations exposed to solid objects of 1 mm and splashing water when the cable entry and mating connection are correctly assembled.

DIMENSIONS & TECHNICAL DRAWING

Mounting Footprint And Cable Entry

The supplied drawing identifies the fixed mounting and entry dimensions used to plan the installation surface.

Red Wall Mounted Plug DT514 and DT524 dimensioned mounting drawing

Installation Dimensions

The drawing defines a 70 mm enclosure width and 57.5 mm mounting-center pitch. Use the exact DT514 or DT524 drawing for the model-dependent overall depth and height.

  • Four Ø5 mm fixing holes
  • Ø20 mm cable-entry opening
  • 33 mm and 17 mm vertical reference dimensions
  • Rigid, flat mounting surface required

MATERIALS & MANUFACTURING

Housing, Contacts And Assembly

The construction separates the insulating enclosure, current-carrying pins and fixed mounting hardware for a serviceable equipment inlet.

Enclosure And Contacts

Flame-retardant engineering thermoplastic housing with solid brass current-carrying pins.

Manufacturing Process

Injection-molded enclosure parts, machined contacts, terminal assembly and electrical and mechanical inspection.

Color And Finish

Color-molded red interface and white base with corrosion-resistant contact and fastener surfaces.

PERFORMANCE & WORKING CONDITIONS

Electrical And Environmental Operating Window

Use the selected current size only within a matching circuit, cable, protective device and female connector system.

16 A / 32 ARated Current By Model
380-415 VAC, 50/60 Hz
IP44Correctly Installed And Mated
5,000Insertion And Withdrawal Cycles
Power SystemThree-Phase AC With Protective Earth
Ambient Temperature-30 °C To +50 °C
Pole And Clock Position4-Pole, 3P+E, 6h
Installation BoundaryFlat Rigid Surface And Sealed Cable Entry

CUSTOMIZATION

Order Configuration And Commercial Options

Current size, marking, packing and documentation can be selected without altering the standardized electrical interface.

  • Current Variant
    DT514 for 16 A circuits or DT524 for 32 A circuits.
  • Marking
    Model, electrical rating, buyer item code and batch reference on product and cartons.
  • Packaging
    Carton quantity, private labels and palletization for bulk shipments.
  • Documentation
    Specification sheets, inspection records, packing lists and applicable conformity documents.
  • Sample Support
    Paid samples for mechanical fit, electrical configuration and mating checks.
  • Safety Boundary
    Current rating, pole layout, protective-earth position and interface geometry remain fixed for each ordered model.

USE & SAFETY INSTRUCTIONS

Install, Connect And Maintain The Inlet Safely

Qualified electrical personnel should complete the fixed wiring, mating checks and commissioning within local installation rules.

01

Isolate And Verify

Disconnect all power, prevent re-energization and verify absence of voltage. Check the model, current rating, 380-415 V system, four-pole layout, 6h position and IP44 condition.

02

Mount And Wire

Fix the base on a flat rigid surface. Route cable through the Ø20 mm entry, terminate L1/L2/L3/PE to the marked terminals and keep cable load off the terminals.

03

Mate And Energize

Use a compatible four-pole 6h female connector of the same current size. Close and secure the connection before energizing, then check phase sequence where the load requires it.

04

Inspect And Maintain

De-energize before service. Inspect the housing, pins, terminals, fasteners and cable-entry seal; replace damaged parts instead of bypassing the keying or earth contact.

Electrical Safety NoticeNever remove the protective-earth connection, alter the keying, exceed the selected current rating or use IP44 as a claim for immersion or high-pressure washing.

PURCHASING CONDITIONS

Samples, MOQ, Lead Time And Shipping

Order the model, current rating, packing and documentation as one controlled configuration.

  • MOQ100 pieces per model and electrical configuration
  • Sample Policy1-5 paid samples; sample cost can be credited against the first qualifying bulk order
  • Sample Lead Time3-7 working days for standard configurations
  • Bulk Lead Time15-25 working days after order and artwork approval
  • Price BasisEXW Yueqing or FOB Ningbo/Shanghai, quoted by model, quantity and packing
  • PackagingProtective inner pack, labeled export carton and palletized consolidation where required
  • Payment Terms30% deposit with order and 70% balance before shipment
  • Shipping SupportCourier or air for samples; sea freight or nominated forwarding for bulk orders

PRE-SALES & AFTER-SALES SERVICE

Support From Circuit Selection To Repeat Orders

Technical and order support keeps the selected electrical configuration consistent from sample to bulk supply.

Before Ordering

Review voltage, current, poles, 6h position, mating connector, conductor size and mounting drawing.

During Production

Maintain model and batch identification, inspect terminal assembly and verify packing labels against the order.

After Delivery

Provide installation guidance, compatibility review and batch-based fault analysis for replacement or repeat supply.

FACTORY & MANUFACTURER

DTCEE Manufacturing And Order Support

Product identity and manufacturing scope remain traceable through the company and its management-system records.

Manufacturer

Yueqing Datong Electrical Co., Ltd., Henghe Industrial Zone, Panshi Town, Yueqing City, Zhejiang Province, China.

Production Scope

Production and sales of industrial plugs, industrial sockets and industrial appliance couplers under the DTCEE brand.

Order Support

Model selection, sample coordination, batch identification, export packing and supporting order documents.

CERTIFICATES & STANDARDS

Applicable Standards And Management Systems

Scope, model configuration and validity should be matched to the destination-market approval file used for the order.

  • Conformity Verification DPWD/2375/26/KG/26Industrial plugs, sockets, couplers and connectors
  • EN IEC 60309-1:2022 And EN IEC 60309-2:2022Referenced product standards
  • ISO 9001:2015, ISO 14001:2015 And ISO 45001:2018Management systems valid through 24 May 2029, subject to surveillance
  • Document PackageUse the current scope and validity record for order approval

REQUEST A TECHNICAL QUOTE

Send The Model, Circuit And Order Quantity

Include the required current rating, mating connector, cable size, quantity and destination so the quotation uses one complete configuration.

  • Phone: +86 13336970867
  • Email: info@dtcee.com
  • WhatsApp: +86 13336970867
  • Address: Henghe Industrial Zone, Panshi Town, Yueqing City, Zhejiang Province, China

Contact details are used only to respond to this product inquiry.