PRODUCT SECONDARY CATEGORY PAGE
Wall Mounted Plug
DTCEE supplies Wall Mounted Plug families for fixed industrial power connections, with scoped models covering 16 A/32 A and 63 A/125 A ratings, 230 V/400 V page-listed configurations and IP44/IP67 options. Yueqing Datong Electrical Co., Ltd. supports model, cable, mating and installation review; send your conditions and quantity for a technical quote.
Selection should follow confirmed model data, not appearance alone.
PROCUREMENT DECISION CHECKLIST
Order A Wall Mounted Plug Against A Complete Specification.
For procurement, OEM and engineering teams, the fastest way to avoid a mismatch is to confirm the electrical, interface, environment and document inputs together before requesting a quote.
1. Define The Interface
Specify fixed wall-mounted plug, mating socket or equipment input, plus the IEC/EN 60309 family and pin/pole role.
2. Confirm Electrical Data
Send rated voltage, frequency, current, phase arrangement and clock position; colour alone is not enough.
3. Match The Installation
Share cable cross-section, wall or box fixing, cable entry direction, clearance and required IP condition.
4. Set The Order Scope
State model pair, quantity, destination and requested documents; sample, MOQ, stock, lead time and Incoterms are confirmed in writing.
MOUNTING AND MATING VERIFICATION
Verify The Mounting And Mating Details Before Release.
The public model pages confirm the main ratings, but final fit depends on the selected model’s dimensions, cable range, mating accessory and installation state.
Model Data
DT513/DT523 list 1–2.5 / 2.5–6 mm² cable ranges; DTN5131/DTN5231, DT5141/DT5241 and DT5142/DT5242 list 1.5–2.5 / 4–6 mm².
High-Current Option
DTN5331/DTN5431 lists 10–16 mm² cable size; confirm the actual current, voltage, pole and mating configuration before ordering.
Ingress Condition
Use IP44 or IP67 only within the product’s declared installation state; IP67 is not a permanent-immersion or high-pressure-washing claim.
Release File
Request the applicable data sheet, dimension drawing, wiring information and configuration-specific conformity or inspection documents.
CATEGORY INTRODUCTION & BUYER PAIN POINTS
Understand The Category Before Comparing Models.
Use the category boundary, equipment fit and buyer risks as the comparison baseline.
What This Category Covers
Wall Mounted Plug products are fixed-mount industrial plug assemblies used on walls, boxes or equipment structures. The scoped DTCEE pages cover 3-pin and 4-pin families, 230 V or 400 V page-listed ratings, and 16 A/32 A through 63 A/125 A current groups; confirm the exact plug/socket role before pairing.
Where Buyers Lose Time
The main purchase risks are selecting by colour or the word plug alone, mismatching current, voltage, poles or clock position, or fitting an IP-rated part without checking the complete connected condition. These errors can cause misconnection, water ingress or rework.
PRODUCT REQUIREMENTS FOR THIS DUTY
Translate The Operating Condition Into Measurable Requirements.
Use the selected model data and installation conditions as the purchasing baseline.
Electrical Rating And Pole Configuration
Verify rated current (16 A/32 A or 63 A/125 A per selected family), rated voltage, frequency, phase arrangement, pole function and clock position against the equipment circuit; do not infer them from colour.
Environment And IP Condition
DTCEE scoped pages list IP44 or IP67. IP44 covers stated splash/solid-object protection; IP67 is for specified temporary immersion conditions, not permanent immersion or automatic high-pressure washing. Confirm connected/unconnected state, cover and locking.
Cable, Mounting And Interface Fit
Use the selected model’s dimensions and cable cross-section: 1–2.5 / 2.5–6 mm² on DT513/DT523; 1.5–2.5 / 4–6 mm² on DTN5131/DTN5231, DT5141/DT5241 and DT5142/DT5242; 10–16 mm² listed for DTN5331/DTN5431. Confirm wall fixing, cable entry, mating socket and clearance.
Documentation And Order Inputs
Send the exact model pair, current/voltage/poles, cable size, installation condition, quantity, destination and required documents for a written quote; MOQ, sample, stock, lead time and Incoterms are confirmed per order.
RECOMMENDED PRODUCTS / MODELS
Start With A Verified Fit, Then Confirm The Final Specification.
This Wall Mounted Plug range covers fixed industrial connection points across 16 A/32 A and 63 A/125 A families. Select by rated voltage, current, pole configuration, IP condition and cable range; verify the mating socket, clock position and installation dimensions before ordering.

DT513 / DT523 Wall-Mounted Plug
Fixed wall-mounted industrial power connection; verify mating socket and fixed-wiring role.
- Application / fitWall-mounted fixed connection
- Pressure / load range16 A / 32 A rated current
- MaterialBrass conductor; high-strength engineering-plastic shell
- Interface standardIEC/EN 60309 family; 3 pins; confirm clock position and mating type

DTN5131 / DTN5231 Wall-Mounted Plug
Fixed wall-mounted industrial power connection; use the PA-shell and conductor configuration shown for this model pair.
- Application / fitWall-mounted fixed connection
- Pressure / load range16 A / 32 A rated current
- MaterialNickel-plated brass conductor; Nylon (PA) shell
- Interface standardIEC/EN 60309 family; 3 pins; confirm clock position and mating type

DT5141 / DT5241 Wall-Mounted Plug
Fixed wall-mounted industrial power connection for the listed 400 V, 4-pin configuration; verify phase arrangement and mating part.
- Application / fitWall-mounted fixed connection
- Pressure / load range16 A / 32 A rated current
- MaterialBrass conductor; Nylon (PA) shell
- Interface standardIEC/EN 60309 family; 4 pins; confirm clock position and mating type

DTN5331 / DTN5431 Wall-Mounted Plug
Higher-current wall-mounted connection family; confirm the exact current, voltage, pole and mating configuration before release.
- Application / fitWall-mounted fixed connection
- Pressure / load range63 A / 125 A rated current (page-listed family)
- MaterialNickel-plated brass conductor; Nylon (PA) shell
- Interface standardIEC/EN 60309 family; 3 pins; confirm voltage, clock position and mating type

DT5142 / DT5242 Wall-Mounted Plug
Fixed wall-mounted industrial power connection where the complete installation requires the page-listed IP67 configuration.
- Application / fitWall-mounted fixed connection
- Pressure / load range16 A / 32 A rated current
- MaterialBrass conductor; Nylon (PA) shell
- Interface standardIEC/EN 60309 family; 4 pins; confirm clock position and mating type
PRODUCTION & DELIVERY
Make The Commercial Route Clear Before The First Inquiry.
Commercial terms are confirmed for the selected model, configuration, quantity and destination.
Confirm model, electrical configuration, quantity and destination before quoting sample availability, charge and timing.
Submit the exact model pair and configuration for a quantity-based quotation; inspection scope and packing terms are confirmed in writing.
Align replenishment quantity, packaging, documents and delivery conditions in the quotation; do not assume a fixed MOQ across model families.
Availability and lead time are confirmed per model, configuration, quantity and order approval; the page makes no blanket ready-to-ship claim.
Confirm destination, carrier, export documents and Incoterms in the quotation before dispatch.
Request the applicable data sheet, dimension drawing, wiring information and configuration-specific inspection or conformity documents.
APPLICATION PAIN POINTS & SOLUTIONS
Connect Each Recommended Model To A Specific Failure Mode.
Each line ties a purchasing risk to verified model data; no service-life claim is made here.
DT513 / DT523 · Current, voltage or pole data is incomplete when a wall-mounted plug is selected by appearance.
Why it matters: Current, voltage or pole data is incomplete when a wall-mounted plug is selected by appearance. Specification response: The scoped page lists 16 A/32 A, 230 V, 3 pins, IP44 and 1–2.5 / 2.5–6 mm² cable ranges; confirm the mating accessory and clock position before release.
DTN5131 / DTN5231 · Plastic shell, conductor and IP requirements are mixed during replacement.
Why it matters: Plastic shell, conductor and IP requirements are mixed during replacement. Specification response: The scoped page lists nickel-plated brass conductor, Nylon PA shell, 16 A/32 A, 230 V, 3 pins, IP44 and 1.5–2.5 / 4–6 mm² cable ranges; use the page-listed configuration, not a family-level assumption.
DT5141 / DT5241 · A four-pin part is chosen without checking the 400 V circuit and cable entry.
Why it matters: A four-pin part is chosen without checking the 400 V circuit and cable entry. Specification response: The scoped page lists brass conductor, Nylon PA shell, 16 A/32 A, 400 V, 4 pins, IP44 and 1.5–2.5 / 4–6 mm² cable ranges; verify voltage, phase arrangement and mating part.
DTN5331 / DTN5431 · Higher-current selection is released before the exact voltage, pole and cable conditions are confirmed.
Why it matters: Higher-current selection is released before the exact voltage, pole and cable conditions are confirmed. Specification response: The scoped page lists a 63 A/125 A family, 230 V, 3 pins, IP44 and 10–16 mm² cable size; confirm the exact configuration and mating part before release.
DT5142 / DT5242 · An IP67 option is treated as automatically suitable for every water, cleaning or outdoor condition.
Why it matters: An IP67 option is treated as automatically suitable for every water, cleaning or outdoor condition. Specification response: The scoped page lists 16 A/32 A, 400 V, 4 pins, Nylon PA shell and IP67; confirm the complete connected state, cover, locking and site exposure because IP67 is not permanent immersion or automatic high-pressure-wash approval.
SELECTION / MATERIAL COMPARISON
Show Buyers When One Grade Is A Better Fit Than Another.
Compare verified IP and configuration limits; final pairing still requires model and installation confirmation.
| Grade / model | Best environment | Key advantage | Limit / trade-off |
|---|---|---|---|
| IP44 Wall-Mounted Plug | Indoor, sheltered or splash-exposure conditions within the declared installation state | The scoped DTCEE pages list IP44 16 A/32 A and 63 A/125 A wall-mounted families | Not a substitute for IP67; verify sealing, covers, locking and site exposure. |
| IP67 Wall-Mounted Plug | Dust and specified temporary immersion exposure when the complete connection is installed correctly | Higher stated ingress protection on DT5142/DT5242 and matching IP67 families | Does not mean permanent immersion, high-pressure washing, corrosion, UV or mechanical suitability. |
NON-STANDARD CUSTOM CHANNEL
Have A Drawing Or Unusual Duty? Send The Minimum Information First.
For a non-standard Wall Mounted Plug request, send a drawing or reference file together with required quantity and work email. The engineering team can review model, current/voltage, pole, IP, cable and mounting requirements before a written quote.
FAQ
Questions Buyers Ask Before Ordering.
Answers are based on the scoped model data and procurement checks; final fit remains configuration-specific.
Which Wall Mounted Plug model fits my equipment and duty?
Confirm the plug or socket role, rated voltage, frequency, current, pole function, clock position, IP condition, cable size, mating part and mounting space. The five scoped model pages provide the starting configuration; an engineer confirms the final fit from your equipment data.
What is the MOQ, sample policy and lead time?
MOQ, sample availability, charges, stock status and lead time are confirmed in writing for the selected model, configuration, quantity and destination. Include these inputs in the quote request rather than assuming a family-wide commercial term.
Which material or IP grade should I choose?
Use the selected model data for conductor and shell materials, then match IP44 or IP67 to the complete installation state. IP67 is for specified temporary immersion conditions and does not by itself mean permanent immersion or high-pressure-wash suitability.
Can you provide drawings, inspection or conformity documents?
Request the applicable data sheet, dimension drawing, wiring information and configuration-specific inspection or conformity documents with the quotation. The document set depends on the selected model, market and transaction arrangement.
Do you support non-standard customization?
Send a drawing or reference file with quantity, work email, model or target configuration, cable and mounting conditions. The engineering team reviews the requested changes before a written quotation; safety, interface and document impacts must be confirmed for the final configuration.
REQUEST A TECHNICAL QUOTE
Tell Us The Equipment, Condition And Quantity.
- Phone: 86-13336970867
- Email: info@dtcee.com
- WhatsApp: +86 13336970867
- Address: Henghe Industrial Zone, Panshi Town, Yueqing City, Zhejiang Province, China
DTCEE